Horizontal Pulse Vacuum Steam Sterilizer Printing Deep Drying Function Sterilizing Autoclave
1. Steam Sterilizer Horizontal Pulse Vacuum:
- Enhanced Air and Moisture Removal: The Horizontal Pulse Vacuum system operates by applying a series of vacuum pulses to remove air and moisture from the sterilization chamber before the main sterilization cycle begins. This ensures that porous items, wrapped tools, and hollow objects are thoroughly de-aerated. As a result, steam can reach the items more efficiently, providing complete and consistent sterilization even for complex loads.
- Improved Sterilization of Challenging Loads: The pulse vacuum feature is particularly beneficial for delicate or irregularly shaped items, such as surgical kits wrapped in layers or hollow surgical instruments. The vacuum pulses force out air trapped inside cavities or layers, ensuring that steam penetrates evenly, achieving a deeper level of sterilization. This is essential for sterilizing items with multiple layers of packaging or intricate designs that may be difficult to reach with conventional sterilization methods.
- Faster Sterilization Cycles: By efficiently removing air and moisture, the Horizontal Pulse Vacuum reduces the time needed to achieve optimal sterilizing conditions. The faster penetration of steam ensures that the overall sterilization process is quicker, which is especially important in busy hospital or clinic environments where quick turnaround times are necessary. This feature improves throughput without compromising sterilization quality.
- Higher Sterilization Confidence: The vacuum pulse system enhances reliability in sterilization, as it helps to eliminate pockets of air or moisture that can interfere with steam exposure. This reduces the likelihood of incomplete sterilization, which is critical for ensuring patient safety, particularly when sterilizing sensitive surgical instruments or other high-risk equipment.
2. Steam Sterilizer Printing Function:
- Automatic Cycle Documentation: The Printing Function allows the sterilizer to automatically print out detailed records of each sterilization cycle, including parameters like temperature, pressure, time, and cycle number. This provides a convenient and reliable audit trail for healthcare facilities, ensuring compliance with stringent sterilization standards and regulations.
- Real-Time Data Access: Having a built-in printer ensures immediate access to sterilization results, which can be particularly useful for verifying that all parameters were met before using or storing sterilized items. Medical personnel can quickly review sterilization data without needing to consult external systems or wait for manual reports, streamlining the workflow and reducing the risk of human error in tracking sterilization performance.
- Enhanced Traceability and Accountability: The printed records help maintain a clear history of each sterilization event, which is vital for ensuring that each batch of instruments has been properly sterilized. This enhances the traceability of sterilized items, ensuring that each set of instruments can be tracked back to the specific cycle that processed them, a key factor in maintaining high standards of quality control.
- Regulatory Compliance: The printing function supports compliance with health and safety regulations by providing hard copies of cycle records for inspection. These records are often required in accredited healthcare settings to demonstrate adherence to sterilization protocols, making it easier for facilities to pass audits and inspections.
3. Steam Sterilizer Deep Drying Function:
- Thorough Drying of Sterilized Items: The Deep Drying Function is an integral part of the sterilization process that ensures instruments and materials are completely dry after the sterilization cycle. Unlike standard drying functions, the Deep Drying feature uses advanced techniques to remove any residual moisture that may remain in porous materials or hollow instruments. This helps to prevent contamination or rusting that could occur if moisture is left behind.
- Prevents Recontamination: One of the biggest concerns with sterilization is the possibility of moisture leading to recontamination. The Deep Drying Function ensures that once the sterilization process is complete, the items are not exposed to moisture that could harbor bacteria or pathogens. This feature is especially important when sterilizing sensitive medical instruments, as even small amounts of moisture can compromise their sterility.
- Enhanced Protection for Instruments: For delicate or precision equipment, moisture left behind after sterilization can cause damage or rusting. The Deep Drying Function mitigates this risk, providing better protection for valuable instruments and extending their operational life. This is particularly important for surgical tools and devices that are exposed to high humidity environments, as the drying function helps to keep them in optimal condition.
- Time-Saving and Efficiency: The Deep Drying cycle automates the drying process, saving medical staff from the labor-intensive task of manually drying instruments after sterilization. This automated drying reduces the risk of cross-contamination from manual handling and speeds up the overall process, contributing to higher throughput and more efficient use of time in busy hospital settings.
Steam Sterilizer Technical Data
MODEL | BT-100YV | BT-150YV | BT-200YV | BT-300YV |
Technical Data |
Sterilizing chamber volume | 100L φ440×670mm | 150L Φ440×1000mm | 200L Φ515×1000mm | 300L Φ600×1080 |
Working pressure | 0.22Mpa |
Working temperature | 134℃ |
Temperature adjust range | 115-134℃ |
Time for sterilization | 0-99min |
Time for drying | 0-99min |
Heat average | ≤±2℃ |
Vacuum limit | -0.08Mpa |
Power | 10kw/380V 50Hz | 10kw/380V 50Hz | 10kw/380V 50Hz | 13kw/380V 50Hz |
Dimension(mm) | 1400×660×1640 | 1400×660×1640 | 1400×750×1740 | 1520×850×1850 |
Exterior package dimension(mm) | 1560×920×1820 | 1560×820×1820 | 1560×910×1880 | 1680×1080×2100 |
G.W/N.W | 430/340kg | 440/350kg | 460/370Kg | 580/470Kg | |
Steam Sterilizer Use
The sterilizer uses pressure saturated steam to sterilize the articles. Pulsating vacuum exhaust is used to eliminate the influence of cold air on temperature. Finally, vacuum dehumidification combined with jacket drying is used to dry the articles. It makes use of the physical characteristics that pressure saturated steam can release a large amount of latent heat when condensing, so that the articles to be sterilized are in a high temperature and humidity state. After a certain period of time, all bacteria and spore tissues in the articles are destroyed, so as to achieve the purpose of sterilization. Mainly used in hospitals, chemical, food, scientific research, pharmaceutical and other units, surgical instruments
Steam Sterilizer Characteristics
• Automatically controlled the sterilizing process, easy to operate.
• It has three times or more pulsating vacuum. It is suitable for all kinds of packed, non packed, hollow porous and internal pipeline instruments.
• The sterilizer is equipped with a steam generator, and one set of movable sterilization plate is randomly adapted.
• The inner cavity of the sterilizer is a circular double-layer design, which is composed of a sterilization chamber and a jacket, and has the function of deep drying.
• With printing function, the printer can record the whole process of sterilization.
• With Bowie & test function for steam penetration test.
• With over-temperature, over-pressure auto-protect.
• Safety interlock device: when the door is not closed tightly, steam can not enter the main body of the inner layer and give an alarm. When the pressure in the sterilization room is greater than 0.027mpa, the door is interlocked and cannot be opened.
• Over-pressure protection: when the pressure exceeds the working pressure, the safety valve will automatically relieve the pressure
• Low water level protection device: the water can not be started until the high water level, and it will be automatically cut off when the low water level is short of water.
• Over current protection: when the current overload, the power circuit breaker will automatically cut off the power supply.
• Sealing door: manual door opening and closing, radial rod rotary table type, equipped with two-stage self-locking, interlocking safety device, single door (double door optional), with pressure safety interlock device.
• The sterilization room is made of high quality stainless steel.