Zhangjiagang Bestran Technology Co., Ltd.

We provide quality hospital furniture and surgical equipment!

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Medical Autoclave /

Automatic Program Control Medical Autoclave With Printer High Pressure Steam Sterilizer

Contact Now
Zhangjiagang Bestran Technology Co., Ltd.
Visit Website
Country/Region:china
Contact Person:MrsMia Zhang
Contact Now

Automatic Program Control Medical Autoclave With Printer High Pressure Steam Sterilizer

Ask Latest Price
Video Channel
Brand Name :Bestran
Model Number :BT-35HV
Certification :ISO9001,ISO13485
Place of Origin :China
MOQ :1pc
Price :Negotiable
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :300pcs per Month
Delivery Time :7-15 days
Packaging Details :1560×820×1820mm, 430/340 KG,1pc/plywood case
Product Name :Vacuum Autoclave
Printer :Yes
Drying Function :pulse vacuum drying
Sterilizing chamber volume :35L 50L 75L 100L
working pressure :0.22 MPa
working  temperature :134℃
Adjustment of temperature :105~134℃
Max working pressure :0.23 Mpa
Door Safety Lock System :Yes
Material :stainless steel structure
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Medical Vacuum Autoclave With Printer High-Pressure Sterilizer Automatic Program Control

1. Vacuum Autoclave With Printer:

  • Automated Documentation and Record Keeping: The inclusion of a printer in the Medical Vacuum Autoclave ensures automatic generation of detailed records for every sterilization cycle. This allows for easy printing of cycle parameters like temperature, pressure, time, and completion status. The printed data serves as an audit trail, which is essential for meeting regulatory requirements, ensuring compliance with healthcare standards, and performing quality assurance checks.
  • Enhanced Traceability for Quality Control: Having a printer integrated directly into the autoclave improves traceability for sterilization processes. Hospitals, clinics, and medical centers can easily track the effectiveness of each sterilization cycle and confirm that instruments were subjected to the appropriate conditions. This traceability is vital in environments where patient safety is critical and documentation is often required for accountability and verification.
  • Real-Time Reporting: The printer enables real-time printing of sterilization results, allowing healthcare professionals to have immediate access to cycle data without needing to rely on external systems. This is especially useful in high-demand settings, where quick access to cycle details can assist in ensuring that instruments are ready for use without unnecessary delays.
  • Convenience and Reduced Human Error: By automating the recording process, the printer minimizes the likelihood of human error in documentation, as all cycle information is automatically generated and printed. This streamlines workflow and reduces the chances of missing or incorrect data entries that could otherwise compromise patient safety or compliance efforts.

2. Vacuum Autoclave 3 Times Pulse Vacuum:

  • Enhanced Air and Moisture Removal: The 3 Times Pulse Vacuum feature significantly improves the sterilization of porous and wrapped items. By applying three pulses of vacuum before the sterilization process begins, this feature effectively removes air and moisture from the chamber, creating a more favorable environment for steam penetration. The improved air removal ensures that sterilizing steam reaches all areas of the instruments, especially those wrapped in layers or in hollow spaces, where trapped air can hinder effective sterilization.
  • Better Steam Penetration and Faster Cycle Times: By removing air and moisture more efficiently, the pulse vacuum system allows for faster steam penetration into instruments and materials, accelerating the sterilization process. This feature is particularly advantageous when sterilizing items that are difficult to sterilize with traditional autoclaves, such as textiles, surgical packs, and equipment with complex shapes.
  • Higher Sterilization Reliability: The 3-pulse vacuum process increases the reliability of sterilization by ensuring that there are no air pockets or moisture left within wrapped or porous items. This thorough vacuum process reduces the risk of inadequate sterilization, which can otherwise occur if air is left behind and prevents the steam from reaching the items fully.
  • Improved Efficiency for Delicate and Complex Loads: For items like surgical instruments, filters, or porous materials that require deep sterilization, the pulse vacuum technology enhances overall sterilization quality. It helps achieve the desired level of sterilization without the need for prolonged cycles, improving efficiency while ensuring that delicate and complex loads are thoroughly decontaminated.

Vacuum Autoclave Technical Data

Model

technical data

BT-35HV BT-50HV BT-75HV BT-100HV
Chamber volume 35L(φ318×450)mm

50L

(φ340×550)mm

75L(φ400×600)mm 100L(φ440×650)mm
working pressure 0.22MPa 0.22MPa 0.22MPa 0.22MPa
Working temperature 134℃ 134℃ 134℃ 134℃
Heat average ≤±1℃ ≤±1℃ ≤±1℃ ≤±1℃
Timer 0~99min 0~99min 0~99min 0~99min
Adjustment of temperature 105~134℃ 105~134℃ 105~134℃ 105~134℃
Power 2.5KW /AC220V.50Hz 3.K0W/AC220V.50Hz 4.5KW /AC220V.50Hz 4.5KW /AC220V.50Hz
Overall dimension 600*410*1030(mm) 690×470×1140(mm) 730*510*1270(mm) 730*550*1305(mm)
Transport dimension 730*500*1170(mm) 760×550×1290(mm) 820*600*1380(mm) 840*640*1410(mm)
G.W/N.W 96Kg/ 77Kg 120Kg/ 100Kg 140Kg/ 118Kg 160Kg/ 128Kg

Vacuum Autoclave Characteristics:

1. Automatically controlled by computer, digital display of working status, touch type key.

2. Dynamically showed the temperature, pressure time and vacuum rate and the full cycle

3. fully automatically route for water inlet, pulse vacuum,heating, sterilizing, draining, exhausting, vacuum drying.

4. 3 times pulse vacuum,which make the vacuum rate as -0.081mpa,and ensure the high extracting of inner air from dressing, A.B type hollowed appliance.

5. with 4 fixed program for appliance, medical dressing, rubbers and fluid,and the user can also set the program as they need.

6. equipped with the PT/TT testing connector, easy to run the testing.

7. Multiple pulse vacuum drying after sterilizing, ensure the nice sterilizing.

8. Equipped with bacteria filter, ensure the sterile air enter the inner vacuum environment,avoid the second contamination.

9. hand wheel type of quick-open door structure,self-inflating type seal.

10. adopted with immersed heating, with high heating efficiency.

11. steam-water inner circulation system:no steam discharge, and the environment for sterilizing will be clean and dry.

12. automatically shut off with beep reminding after sterilization.

13. fully high quality stainless, equipped with double stainless steel basket.

Automatic Program Control Medical Autoclave With Printer High Pressure Steam SterilizerAutomatic Program Control Medical Autoclave With Printer High Pressure Steam Sterilizer

Inquiry Cart 0