Add to Cart
Biphasic Defibrillator Monitor Medical Manual External Synchronous Asynchronous
Biphasic Defibrillator Features:
A Biphasic Defibrillator is used primarily to treat patients experiencing life-threatening cardiac arrhythmias, such as ventricular fibrillation (VF) and ventricular tachycardia (VT), by delivering a controlled electrical shock to the heart to restore a normal rhythm
The Biphasic Defibrillator is essential in the management of life-threatening arrhythmias and cardiac emergencies. Its usage spans from emergency care settings (ambulances, ERs) to hospital care (ICUs, post-surgical recovery), providing effective and safe defibrillation with minimal risk of harm to the heart. Its biphasic technology ensures that fewer shocks are needed, improving patient outcomes and reducing the potential for heart tissue damage.
Biphasic Defibrillator Technical Parameter:
Biphasic Defibrillator Display | Screen Type:High-resolution display, TFT colour display Screen Size: 7 inches (17.7cm) diagonally Sweep Speed: 12.5/25/50mm/sec Information: Heart Rate, Lead, Alarm On/Off, Delivered Energy Resolution:800X480 |
Biphasic Defibrillator ECG | Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles. Lead Selection: Displayed on monitor, paddles, I, II, III,AVR, AVL, AVF, V. ECG Size: 2.5,5, 10, 20, 30 mm/mV display on monitor. Heart Rate: 20-350BPM. Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation |
Biphasic Defibrillator Defibrillator | Waveform: Biphasic Defibrillator type: Manual External Synchronous/Asynchronous Defibrillation. Charge Time: Less than 10 seconds to 360 Joules Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts. Energy Selection: Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules Standard Adult/Pediatric Paddles: Reusable external adult paddles (pediatric paddles integrated) |
Biphasic Defibrillator Battery Description | Standard Type: Li-ion battery Li1104c 11.1Vdc 4000mAh X2 Standard Capacity: Up to 10 hours ECG monitoring or 60 full-energy discharges. Low Battery Indicator: Flashing low battery icon on display and Bat Indicator on the panel of defi-monitor be on Recharge Rate: 80% in 3 hours. 100% in 5 hours. |
Biphasic Defibrillator Built-in Recorder | Paper: 50mm thermal. Printing Method: High-resolution, thermal print head. Record date, time ,sweep speed, waveform gain, heart rate, energy (joule) and ECG waveform Print mode HR exceed limits alarm recording Auto timed recording Real-Time Recording Defibrillation discharge trigger recording |
Biphasic Defibrillator Power | AC-DC dual-use: Use the batteries,AC100V~240V,50/60 Hz. Vehicle Voltage(Option): DC 12V |
Biphasic Defibrillator Main unit | Portable Dimensions:L320xW205xH410 Weight:7.5kg |
Biphasic Defibrillator Pulse Oximeter (Optional) | Display: Spo2 value,waveform, Pulse Probe: Standard adult finger clip Range: 0-99% for adult, pediatric and neonatal patients |
Biphasic Defibrillator AED (Optional) | Voice prompts and screen prompts. Energy Programmable Sequence:200,300,360 Joules; 150,150,200 Joules; 50, 75, 100 Joules; 30, 30, 50 Joules; Discharge Control: Control on device front panel. |
Biphasic Defibrillator Usage
A biphasic defibrillator is primarily used to treat patients with life-threatening cardiac arrhythmias, such as ventricular fibrillation (VF) and ventricular tachycardia (VT), by delivering a controlled electrical shock to the heart to restore a normal rhythm.