Zhangjiagang Bestran Technology Co., Ltd.

We provide quality hospital furniture and surgical equipment!

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Surgical Equipment /

10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child

Contact Now
Zhangjiagang Bestran Technology Co., Ltd.
Visit Website
Country/Region:china
Contact Person:MrsMia Zhang
Contact Now

10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child

Ask Latest Price
Video Channel
Brand Name :Bestran
Model Number :BT-2000J5
Certification :CE
Place of Origin :China
MOQ :1pc
Price :Negotiable
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :300pcs per Month
Delivery Time :3-5 days
Packaging Details :L940*W790*H1270 MM small:L700*W680*H370 MM N.W./G.W.:76/86KG; N.W./G.W.:22/28KG; (Carton with foam inside)
Product Name :Anesthesia Machine
Screen :10.4 '' LCD Display Screen
Suitable :Adult & Child
Working Mode :Closed; Semi-Closed; Semi-Open
Circuit :Breathing circuit integrated standards
Mode :pneumatically powered and electrically controlled system
Respriation Mode :IPPV,SIPPV,IMV,SIMV,VCV,PCV,PEEP,SIGH,Manu
Vaporizer :2 vaporizers (Enflurane/Isoflurane/Sevoflurane, Option: Halothane)
PEEP :0 ~ 2.0 kPa
Tidal volum :0-1500ml
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

10.4 Inch Anesthesia Machine Workstation 2 Vaporizers Medical Equipment Adult & Child

The 10.4" LCD display screen and 2 vaporizers on an anesthesia machine provide distinct advantages, enhancing usability, safety, and flexibility in clinical settings. Here's a breakdown of the benefits associated with these features, framed in a way that differs from standard descriptions:

1. Anesthesia Machine 10.4" LCD Display Screen:

  • User-Friendly Interface: The large 10.4-inch LCD touch screen offers an intuitive and interactive interface, which makes it easier for clinicians to monitor and adjust critical settings during surgery. Unlike smaller screens or traditional dial-based systems, the larger display provides a comprehensive view of key parameters such as oxygen flow, anesthetic agent concentrations, ventilation settings, and alarms. This reduces the time spent navigating through menus or adjusting settings manually, particularly in fast-paced operating environments.
  • Clear, Real-Time Data Visualization: The LCD screen can present real-time graphical waveforms, such as pressure, volume, and flow curves, which allow for immediate assessment of the patient’s respiratory and anesthetic status. The high resolution and size of the screen ensure that these waveforms and numerical values are clearly visible, improving the clinician’s ability to make quick, informed decisions.
  • Reduced Risk of Errors: With larger text and data displayed at once, the risk of missing critical changes or misinterpreting small figures is minimized. This improves clinical accuracy, especially when quick adjustments are necessary during complex procedures.
  • Multifunctional Display Options: The screen is capable of showing multiple parameters simultaneously, and its customizable layout allows healthcare professionals to prioritize the most relevant data points for their specific procedure, streamlining workflow and increasing efficiency.

2. Anesthesia Machine 2 Vaporizers:

  • Flexibility in Anesthetic Agent Delivery: The inclusion of two vaporizers on the anesthesia machine provides flexibility in delivering different anesthetic gases simultaneously, such as sevoflurane and desflurane, or combining a volatile anesthetic with nitrous oxide. This feature is particularly advantageous during surgeries that require varying concentrations of anesthetics depending on the patient's condition or procedure stage.
  • Continuous, Reliable Anesthesia Delivery: Having two vaporizers ensures that if one vaporizer malfunctions, the other can continue functioning, providing a fail-safe mechanism. This redundancy is critical for maintaining a continuous and stable anesthetic delivery without interruption, enhancing patient safety during long or complex surgeries.
  • Customization for Different Patient Needs: With dual vaporizers, the anesthesia machine can be tailored for different patient profiles—administering one anesthetic agent for pediatric patients and another for adult patients, or adjusting concentrations depending on the clinical scenario (e.g., lighter sedation during less invasive procedures and deeper anesthesia during major surgeries). This flexibility allows for more precise anesthetic control, ensuring patient comfort and safety.
  • Reduced Setup Time: The ability to quickly switch between or simultaneously use two vaporizers minimizes the need for equipment changes during surgery. This results in more efficient workflow in the operating room, as anesthesiologists do not need to reconfigure the machine mid-procedure, saving valuable time.

Anesthesia Machine Prospective service and support

This Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.

Anesthesia Machine TECHNIQUES SPECIFICATIONS

TECHNIQUES SPECIFICATIONS
Physical specifications
Screen: 10.4 '' LCD Display Screen
Suitable Adult & Child
Mode: pneumatically powered and electrically controlled system
Working Mode: Closed; Semi-Closed; Semi-Open
Circuit Breathing circuit integrated standards
Flowmeters: 5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min
Trolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unit TWO drawers totally extractable
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa.
safety valve <12.5 kPa
Respiratory Rate 1~99bpm
oxygen concentration in the mixed gas N2O/O2 > 21%
Oxygen Flush: 25~75 L/min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGH
PEEP: 0 ~ 2.0 kPa
Inspiratory trigger pressure -1.0kPa ~ 2.0 kPa
IMV frequency: ..
I/E Ratio: 8:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume 0 ~ 1500 ML
Inspiratory Plateau: 0~1s
O2 Concentration: 21%~100%
Sigh: one deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point
Maximum safety pressure: ≤ 12.5 kPa
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicating upper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating upper alarm: 21% ~100%; lower alarm:10%~80%
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature: 10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement: 100-120 Vac, 50/60 Hz;
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature: -15oC ~ +50oC
Relative humidity: no higher than 95 %
Atmospheric pressure: 86 kPa ~ 106 kPa.
It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Oxygen Alarm It alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume Alarm Lower: 0~12L/Min; Up: 18L/ Min
Power Alarm It Alrmas while AC and DC supply failure ; Keep alraming time: >120s
Air Tract Pressure Alarm Lower: 0.2kPa ~5.0 kPa; Up: 0.3kPa ~ 6.0kPa

10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child10.4 Inch Surgical Equipment Anesthesia Machine Workstation 2 Vaporizers for Adult Child