15.6'' Touch LCD Screen Medical ICU Ventilator Neonatal Pediatric And Adult Mode Built-In Battery
The 15.6'' Touch LCD Screen and the suitable for Neonatal, Pediatric, and Adult modes features of an ICU ventilator offer substantial advantages in versatility, ease of use, and broad patient applicability. Here's a breakdown of their unique benefits:
1. ICU Ventilator 15.6'' Touch LCD Screen:
- Intuitive Interface for Quick Adjustments: The large 15.6-inch touch screen simplifies interaction with the ventilator, offering an intuitive interface that enables healthcare providers to quickly adjust settings with just a tap. This is particularly beneficial in high-stress environments like the ICU, where rapid, accurate adjustments are crucial for patient care.
- Enhanced Readability and Visual Data Display: With a significantly larger screen size, clinicians can view a greater amount of data at once. Key parameters, such as tidal volume, airway pressure, and oxygen levels, are presented clearly, reducing the time spent navigating through menus and allowing for quicker decision-making. The touch interface further allows clinicians to zoom in on specific data trends or alarms without difficulty.
- Real-time Waveform Analysis: The 15.6” screen displays real-time waveforms, such as pressure, volume, and flow curves. This real-time graphical representation of respiratory parameters makes it easier to detect early signs of issues like ventilator-induced lung injury or air leaks, allowing for quicker intervention.
- Multi-functionality: The touch screen not only shows essential monitoring data but can also display alarms, settings, and patient-specific information. This multi-functionality reduces the need for additional equipment or manual logging, enhancing workflow efficiency in critical care settings.
2. ICU Ventilator Suitable for Neonatal, Pediatric, and Adult Modes:
- Broad Patient Range: The ability to cater to neonates, pediatric patients, and adults with a single device is a major advantage in busy ICUs or emergency settings where different patient age groups may need to be treated simultaneously. This flexibility ensures that the same ventilator can be used across a wide variety of age groups, reducing the need for multiple specialized devices.
- Adaptable Ventilation Settings: For each patient group, the ventilator can automatically adjust key parameters (e.g., tidal volume, respiratory rate) to meet the specific needs of neonates, children, and adults. This feature ensures that the ventilator provides optimal support tailored to each patient's size and respiratory requirements, improving both safety and effectiveness in diverse clinical scenarios.
- Ease of Transition Between Patient Groups: With preset modes and automated adjustments, transitioning from neonatal to pediatric or adult patients becomes seamless, reducing the potential for human error and saving valuable time during emergencies or patient transfers.
- Customized Alarms and Alerts: Depending on the patient's age group, the ventilator can set specific alarm thresholds for each mode. For instance, neonatal settings might require more sensitive parameters and lower pressures compared to adult modes. This ensures that alarms are relevant and appropriately tailored to each age group, enhancing patient safety.
ICU Ventilator Key Differentiators from Other Models:
- Larger Screen for Comprehensive Overview: Unlike smaller screens, the 15.6'' LCD offers an expansive view that reduces the need for toggling between screens, allowing for more efficient monitoring. Many traditional ventilators have smaller, less interactive displays that require more time to interpret critical information.
- Integrated Pediatric and Neonatal Support: While many ventilators are designed only for adults, this model’s ability to seamlessly switch between neonatal, pediatric, and adult modes makes it more versatile and suitable for multidisciplinary environments where care is needed across all patient ages. This flexibility is especially beneficial in hospitals that treat a broad range of patients, from premature infants to elderly adults.
- Time-Saving and Error-Reducing Features: The combination of a large touch screen and adaptable modes minimizes setup errors and increases clinical efficiency. Clinicians can focus more on patient care rather than adjusting or troubleshooting the machine, which is often the case with older models that require more manual input and calibration.
ICU Ventilator Technical Parameter:
Ventilation mode | V-A/C, P-A/C, V-SIMV, P-SIMV, CPAP/PSV, PRVC,PRVC- SIMV,DuoLevel, APRV, CPRV, PSV-S/T, PSV, NCPAP, SIGH, MANU |
Working condition | Voltage: 100 - 240V Frequency: 50/60Hz Input power: 100VA Gas source: O2 (Medical grade) Gas pressure: 280 kPa ~ 600 kPa Ambient temperature range: + 5 ℃ ~ + 40 ℃ |
Alarm and protection | High airway pressure alarm Suffocation warning High tidal volume alarm Oxygen deficit High tidal volume alarm High ETCO2 Alarm High minute volume alarm Low ETCO2 Alarm Low minute volume alarm High respiratory rate alarm High oxygen concentration alarm Low respiratory rate alarm Low oxygen concentration alarm Pressure safety relief valve High positive end-tidal pressure alarm Continuous pressure alarm |
ICU Ventilator Feature:
- Electronically driven and electronically control 15.6 Inches colorful touch LCD screen
- Volume control and pressure limit
- Both non-invasive and invasive ventilation mode Various alarming function
- Compliance compensation function
- Built-in battery, when AC power failure, automatic exchange to backup power
- Same brand medical trolley ETCO2 monitoring
- SPO2 monitoring
- Operation key freeze function Oxygenation function
- Suction function
- Oxygen therapy function
ICU Ventilator Application
- This product is intended for use in an intensive care unit within a specialized medical facility, or during transit within a specialized medical facility. It is used for ventilation assistance and respiratory support for adult,pediatric and neonatal.
- This product should be handled by well-trained, authorized medical person.
- This product cannot be used in magnetic resonance imaging (MRI) environments.
ICU Ventilator Safety
- 31 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
- Built-in oxygen concentration sensor, ensure stable precision of oxygen concentration. Easy to move with four casters, easy to stop with two brakes.
- Separate design of electronic circuit and gas flow rate keep safe running of ventilator. Compact long life internal battery can provide emergency power, avoid risk of patient. Self-check before operation, eliminate system mistake.